CASE STUDY:
Orinda City Hall

Orinda, California

Emerald City Hall: Orinda takes cues from mother nature to lessen its footprint

By Jessica Boehland

Tucked into a steep slope in a bedroom community just east of Berkeley, California, rests Orinda City Hall. About 80 percent of the building faces southwest, while the remainder faces west, overlooking a creek and the civic buildings below. A breezeway running between these pieces allows pedestrians to walk through the building, maintaining a shortcut to downtown and “symbolizing open government,” according to Henry Siegel, FAIA, principal at Siegel & Strain Architects. The two-story, 14,000-square-foot building houses a community room as well as Orinda’s administrative, planning, building, and police departments.

Orinda City Hall
Photo © David Wakely
Orinda City Hall, Orinda, California

Rate this project:
Based on what you have seen and read about this project, how would you grade it? Use the stars below to indicate your assessment, five stars being the highest rating.
----- Advertising -----

KEY PARAMETERS
LOCATION: Orinda, CA (East Hills of San Francisco Bay)

GROSS SQUARE FOOTAGE: 13,900 ft2 (1,291 m2 )

COST: $8 million

COMPLETED: August 2007

ANNUAL PURCHASED ENERGY USE BASED ON

SIMULATION):
60 kBtu/ft2 (677 MJ/m2 ), 63% reduction from base case

ANNUAL CARBON FOOTPRINT (PREDICTED): 16 lbs. CO2/ft2

(76 kg CO2/m2 )

PROGRAM: City Hall Offices: Administrative, Planning, Public Works, Police Departments

Sky Conditions   Temp./Dew Points   Precipitation
Sky Conditions   Temp./Dew Points   Precipitation

TEAM
OWNER: City of Orinda
ARCHITECT AND INTERIOR DESIGNER: Siegel & Strain Architects
ENGINEERS: Tipping Mar + associates (structural), Taylor Engineering (MEP), AfterImage + Space (electrical/lighting), High Sun Engineering (energy)
COMMISSIONING AGENT: Taylor Engineering
GENERAL CONTRACTOR: Ralph Larsen & Son

SOURCES
CURTAIN WALL AND EXTERIOR DOORS: Kawneer
LOW-EMISSIVITY GLAZING: PPG Solarban 60 and 80
SKYLIGHTS: Super Sky
CABINETWORK AND PANELING: Eggers Industries Douglas fir over SierraPine Medite II core
ZERO-VOC AND LOW-VOC PAINTS AND STAINS: Kelly-Moore
RECYCLED-GLASS RESTROOM COUNTERTOPS:
Avonite Surfaces Kaleidoscope
RECYCLED-GLASS TILE FOR BATHROOM FLOORS AND WALLS: Terra Green
RECEPTION DESK: PaperStone
CORK FLOORING: Dodge Cork
CARPET: Interface Tranquility
OFFICE FURNITURE: Allsteel
RECEPTION FURNITURE: Custom designed by Burton Edwards of Siegel & Strain Architects and manufactured by Creative Wood Products
CUSTOM SUNFLOWER-BOARD TABLETOPS: Environ Biocomposites Dakota Burl
ELEVATORS: Kone EcoSpace
SENSOR-ACTIVATED HANDWASHING FAUCETS: Sloan Optima Plus
WATERLESS URINALS AND DUAL-FLUSH VALVES FOR TOILETS: Sloan Valve

According to Siegel, “Our approach is always to start by asking what energy demands we can get rid of and what we can do with natural flows on the site.” Despite the warm climate, the project team found that cross ventilation and the stack effect—via abundant operable windows, clerestories, and skylights—could provide sufficient cooling during much of the year. Mechanical cooling would be needed during the summer, though, and the team set its sights on a compressor-free, energy-saving evaporative system.

The team determined how much cooling an evaporative system could provide and began the work of reducing cooling loads to match. This entailed considerable external shading, through horizontal and vertical elements and with a second floor that cantilevers 30 inches over the first. Inside, they trimmed the lighting power density, installed daylight and occupancy sensors, and even specified that occupants use only low-heat flat-screen computer monitors. “It took a good 30 to 40 percent reduction in loads to get to the goal of eliminating compressors,” says Gwelen Paliaga, senior mechanical designer at Taylor Engineering.

In spite of shading and load-shaving strategies, energy modeling indicated that the evaporative cooler would not be able to keep the building comfortable for about 120 hours each year. In response, the project team turned to ceiling fans, which can make temperatures feel three or four degrees cooler than they really are. This strategy cut the 120 hours of discomfort down to just 28, which was good enough for the owners. “It wasn’t something we’d ever want to push on a client,” says Paliaga, “but the city manager was very supportive and gave us the go-ahead.”

The team chose an indirect/direct evaporative cooling system. This system uses so little energy for cooling it can run on 100 percent outside air. This improves indoor-air quality and cuts down on wasted energy. Paliaga explains, “If people open their windows at the wrong time, it doesn’t waste much energy. It just becomes the path for the exhaust.” Thanks to the evaporative cooling system and the efficiency improvements that allowed its use, the project was anticipated to use 60 percent less energy than allowed by California’s strict Title 24 standards.

The cooling system didn’t perform correctly at first, creating uncomfortable conditions during the building’s first summer. That has been remedied, but another problem remains; Orinda’s police officers wear their bullet-proof vests throughout the day, and not even the ceiling fans can compete with that much insulation. Noting that this requirement wasn’t identified during the design process, Paliaga admitted with regret “the system is not designed to create the cold temperatures that they desire. It’s just not something the building can do.”

Orinda is in a seismically active area, and, since the building is used for emergency response, California requires it to exceed conventional seismic standards by 50 percent. David Mar, structural engineer at Tipping Mar + associates, proposed a series of four steel braces that tilt at their bases. Cables in these braces re-center the building if it rocks. “For a medium earthquake, the frame is rigid to protect the finishes,” says Mar. “But for a giant earthquake, the frame rocks. The finishes get damaged, but the structure realigns itself.” The system cost about $60,000 extra, but the city saw it as a wise investment. “If you neglect durability,” explains Mar, “you invalidate a lot of the life-cycle assessment. In California, seismicity is an environmental issue.”

The budget became a major concern as the design progressed, and at the end of schematic design, the team was asked to shrink the building by 10 percent to cut costs. Value engineering also claimed the planned photovoltaic system as well as sustainably harvested wood, sensors to track open windows, and several other “bells and whistles,” according to Paliaga. The commitment to LEED certification survived, however, and a Gold rating is anticipated. “The city council wanted that credibility,” says Siegel, “and they thought it was an important statement to make for their city.”

share: more »

This article appeared in the November 2008 print issue of GreenSource Magazine.

 Reader Comments:

Sign in to Comment

To write a comment about this story, please sign in. If this is your first time commenting on this site, you will be required to fill out a brief registration form. Your public username will be the beginning of the email address that you enter into the form (everything before the @ symbol). Other than that, none of the information that you enter will be publically displayed.

We welcome comments from all points of view. Off-topic or abusive comments, however, will be removed at the editors’ discretion.

----- Advertising -----
Click here to go to product info Page
Sweets, Search Building Products
Search
Reader Feedback
Most Commented Most Recommended
Rankings reflect comments made in the past 14 days
Rankings reflect comments made in the past 14 days
Recently Posted Reader Photos

View all photo galleries >>
Recent Forum Discussions

View all forum discusions >>